Covers dead, wind, and seismic load calculations per ASCE 7 and PIP STC01015, LRFD load combinations, member sizing, deflection criteria, and thermal expansion provisions. Velocity pressure and exposu...
Contact online >>
Storage racks found in warehouses are not pipe racks, even if they store lengths of pipe. This case study focuses on the design of pipe rack foundations using the engineering software program spMats.
Pipe rack foundations must resist the combined effects of vertical gravity loads, horizontal lateral loads (wind or seismic), and overturning moments. The foundation type and size depend on the soil
In an effort to minimize the cost of process industry facilities, this Practice has been prepared from the technical requirements in the existing standards of major industrial users, contractors, or standards
Structural design requirements for pipe racks, steel modules, modularized equipment skids, vertical and horizontal vessel supports, and vibrating equipment foundations are discussed.
PIP STC01015: Structural design criteria for process industry facilities. Onshore site design requirements and industry standards.
Purpose This Practice provides structural engineering design criteria for the process industries. Scope This Practice describes the minimum requirements for the structural design of
We support original equipment manufacturers (OEMs), skid builders, and engineering, procurement, and construction (EPC) firms with the pipe rack structural design analysis and documentation tailored to
PIP STC01015 Structural Design Criteria. The document outlines the structural design criteria for process industry facilities, detailing minimum requirements and references to relevant codes and
It outlines the guidelines for various structural components such as load requirements, deflection limits, foundation design, and considerations for machinery, with an emphasis on safety and performance
The scope of this document is to provide the calculations for the analysis and design of critical steel pipe rack. The software used for structural analysis and design is STAAD Pro connect
PIP STC01015 Structural Design Criteria. The document outlines the structural design criteria for process industry facilities, detailing minimum requirements and
Prefabricated micro-modular data centers and edge pods, scalable from 5 to 50 racks, ready for 5G and edge AI workloads.
Single-phase immersion cooling tanks and direct-to-chip liquid cooling switches, achieving PUE below 1.1.
GPU-accelerated AI servers, high-density server racks, and network cabinets optimized for AI/ML workloads.
Real-time data center infrastructure management, plus overhead cable trays and fiber bridges for structured cabling.
We provide custom data center infrastructure solutions, from micro-modular DCs to immersion cooling and AI-ready racks.
From design to deployment, our team ensures energy-efficient, scalable, and carrier-grade digital infrastructure.
Al. Jerozolimskie 180, Entrance B, 02-486 Warsaw, Masovian Voivodeship, Poland
+48 571 392 846 | +48 571 392 846 | [email protected]