This publication contains new and updated information as indicated in the following table. The protection and control devices in electrical equipment can be referred to by numbers, with appropriate suffix
In North America protective relays are generally referred to by standard device numbers. Letters are sometimes added to specify the application (IEEE Standard C37.2-2008).
To assist the Protection Engineer in converting from one system to the other, a select list of ANSI device numbers and their IEC equivalents are given in the following figure.
Protection relay selection table Please note before using selection table! number = Number of stages, shots, X = Function supported inputs or outputs O = Function available as option
SELECTION TABLE PROTECTION RELAYS Download this table in PDF Download this table in Excel
The norms of protection of generators, transformers, lines and capacitor banks are also given. The procedures of testing switchgear, instrument transformers and relays are explained in detail.
In the design of electrical power systems, the ANSI Standard Device Numbers denote what features a protective device supports (such as a relay or circuit breaker). These types of
This document lists 57 ANSI codes and their corresponding descriptions of protection devices and functions.
The ANSI(American National Standards Institute) has standardized the codes to be used for protection relays. Each protective function is indicated by a specific no. such as 50 for instantaneous
In the design of electrical power systems, the ANSI Standard Device Numbers denote what features a protective device supports (such as a relay or
This table details ANSI IEEE Standard Device Numbers as used for protective relaying in North America. Suffixes for numbers are also suggested.
Prefabricated micro-modular data centers and edge pods, scalable from 5 to 50 racks, ready for 5G and edge AI workloads.
Single-phase immersion cooling tanks and direct-to-chip liquid cooling switches, achieving PUE below 1.1.
GPU-accelerated AI servers, high-density server racks, and network cabinets optimized for AI/ML workloads.
Real-time data center infrastructure management, plus overhead cable trays and fiber bridges for structured cabling.
We provide custom data center infrastructure solutions, from micro-modular DCs to immersion cooling and AI-ready racks.
From design to deployment, our team ensures energy-efficient, scalable, and carrier-grade digital infrastructure.